Schneider TMC2TI2 Cartridge M221 - 2 temperature inputs - I/O extension,TMC2TI2, Schneider
Schneider TMC2TI2 Cartridge M221 - 2 temperature inputs - I/O extension
range of product |
Modicon M221
|
|
---|---|---|
product or component type |
Analogue input cartridge
|
|
product compatibility |
Modicon M221C
|
|
analogue input number |
2
|
analogue input type |
Thermocouple, input range: - 200...1000 °C for thermocouple J
Thermocouple, input range: - 200...1300 °C for thermocouple K Thermocouple, input range: 0...1760 °C for thermocouple R Thermocouple, input range: 0...1760 °C for thermocouple S Thermocouple, input range: 0...1820 °C for thermocouple B Thermocouple, input range: - 200...400 °C for thermocouple T Thermocouple, input range: - 200...1300 °C for thermocouple N Thermocouple, input range: - 200...800 °C for thermocouple E Thermocouple, input range: 0...2315 °C for thermocouple C Temperature probe, input range: - 60...180 °C (Ni 100/Ni 1000) Temperature probe, input range: - 200...850 °C (Pt 100) Temperature probe, input range: - 200...600 °C (Pt 1000) |
|
---|---|---|
analogue input resolution |
14 bits
|
|
LSB value |
0.1 °C
|
|
sampling duration |
125 ms (thermocouple)
250 ms (temperature probe) |
|
absolute accuracy error |
+/- 0.1 % of full scale Pt 100/Pt 1000, Ni 100/ Ni 1000 25 °C
+/- 0.4 % of full scale thermocouple K - 200...0 °C 25 °C +/- 0.1 % of full scale thermocouple K 0...1300 °C 25 °C +/- 0.4 % of full scale thermocouple J - 200...0 °C 25 °C +/- 0.1 % of full scale thermocouple J 0...1000 °C 25 °C +/- 0.4 % of full scale thermocouple E - 200...0 °C 25 °C +/- 0.1 % of full scale thermocouple E 0...800 °C 25 °C +/- 0.4 % of full scale thermocouple T - 200...0 °C 25 °C +/- 0.1 % of full scale thermocouple T 0...400 °C 25 °C +/- 0.4 % of full scale thermocouple N - 200...0 °C 25 °C +/- 0.1 % of full scale thermocouple N 0...1300 °C 25 °C +/- 6 °C thermocouple R, S 0...200 °C 25 °C +/- 0.1 % of full scale thermocouple R, S 200...1760 °C 25 °C +/- 0.1 % of full scale thermocouple C 0...2315 °C 25 °C |
|
temperature drift |
+/- 0.02 %FS/°C
|
|
repeat accuracy |
+/- 0.5 %FS
|
|
non-linearity |
+/- 0.01 %FS
|
|
cross talk |
<= 1 LSB
|
|
type of cable |
Twisted shielded pairs cable
|
|
electrical connection |
2 screw terminal blocks (pitch 3.81 mm) 1.5 mm² 3 for inputs
|
|
cable distance between devices |
Twisted shielded pairs cable: 30 m for input
|
|
insulation |
Non-insulated between analogue input and internal logic
|
|
height |
41 mm
|
|
depth |
15 mm
|
|
width |
35 mm
|
|
product weight |
0.015 kg
|
|
input impedance |
>= 1 MOhm
|
immunity to microbreaks |
10 ms
|
---|