Schneider ATV6000C213A3333NA3 Medium Voltage Variable Speed Drive ATV6000 - 3.3 kV - 2130 kVA,ATV6000C213A, Schneider
Schneider ATV6000C213A3333NA3 Medium Voltage Variable Speed Drive ATV6000 - 3.3 kV - 2130 kVA
range of product |
Altivar Process ATV6000
|
|
---|---|---|
product or component type |
Medium voltage variable speed drive
|
|
device short name |
ATV6000
|
|
product specific application |
Process and utilities
|
|
assembly style |
In floor-standing enclosure
|
|
provided equipment |
Phase-shifting transformer
Power cells Medium voltage arrestors Plinth Cooling fans Enclosure Human machine interface |
|
colour of enclosure |
Light grey RAL 7035
|
|
IP degree of protection |
IP31 IEC 60529
|
|
type of cooling |
Forced convection
|
|
input type |
18 pulse diode rectifier bridge
|
|
output type |
IGBT inverter cells multilevel PWM
|
|
[Us] rated supply voltage |
3.3 kV +/- 10 %
|
|
supply frequency |
50 Hz +/- 5 %
|
|
network number of phases |
3 phases
|
|
prospective line Isc |
31.5 kA 150 ms
|
|
output voltage |
<= power supply voltage
|
|
permissible temporary current boost |
1.5 x In 60 s heavy duty
1.2 x In 60 s normal duty 1.5 x In 3 s normal duty 1.8 x In 3 s heavy duty |
|
speed drive output frequency |
0.5...120 Hz
|
|
frequency resolution |
0.01 Hz
|
|
product destination |
Asynchronous motors
Permanent magnet motors Synchronous motors |
|
asynchronous motor control profile |
Variable torque standard
Sensorless flux vector control Dynamic energy saving Closed loop vector control Constant torque standard |
|
synchronous motor control profile |
Synchronous motor with external exitation
Vector control Permanent magnet motor |
|
apparent power |
1500 kVA
|
|
THDI |
<= 3 % IEEE 519-1992
|
|
power factor |
96
|
|
motor power kW |
1200 kW normal duty
1070 kW heavy duty |
|
continuous output current |
251 A normal duty
224 A heavy duty |
|
maximum transient current |
376 A 3 s normal duty
420 A 3 s heavy duty |
|
line current |
262 A normal duty
234 A heavy duty |
|
energy efficiency ratio |
0.98 inverter
0.961 total drive including transformer |
|
power losses |
51.1 kW normal duty
45.6 kW heavy duty |
|
cable entry |
Bottom
|
|
electrical connection |
M10 bar main supply
M10 bar motor Terminal 0.25...2.5 mm² control Terminal 1.5...16 mm² cooling fan |
|
cable cross section |
95 mm² line normal duty
70 mm² line heavy duty 95 mm² motor normal duty 70 mm² motor heavy duty |
|
width |
3562 mm
|
|
depth |
1500 mm
|
|
height |
2821 mm
|
|
product weight |
5542 kg
|
|
volume of cooling air |
16933.2 m3/h
|
|
noise level |
83 dB
|
|
EMC filter |
Integrated EN/IEC 61800-3 category C3 control
Integrated EN/IEC 61800-3 category C4 power |
|
display type |
10 inch LCD touch screen multi-language
|
protection type |
Motor phase break motor
Short-circuit protection drive Break on the control circuit drive Fan monitoring drive Overvoltages on the DC bus drive Thermal overload for transformer drive Cabinet overheating drive Overcurrent drive Overload drive IGBT for each cell drive Motor earth fault motor Line supply overvoltage drive Line supply phase loss drive Line supply undervoltage drive Thermal protection motor |
|
---|---|---|
option card |
Communication module Profibus DP V1 slot A
Communication module Profinet slot A Communication module DeviceNet slot A Communication module CANopen daisy chain RJ45 slot A Communication module CANopen SUB-D 9 slot A Communication module CANopen screw terminals slot A Digital and analog I/O extension module slot A/slot B Output relay extension module slot A/slot B Communication module EtherCAT slot A Digital encoder interface module 5/12 V slot B Analog encoder interface module slot B Resolver encoder interface module slot B HTL encoder interface module slot B |
|
connector type |
2 RJ45 Ethernet IP/Modbus TCP on the control block
1 RJ45 Modbus serial on the control block |
|
communication port protocol |
Modbus serial
Ethernet IP/Modbus TCP |
|
supply |
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5
V DC +/- 5 % <= 10 mA overload and short-circuit protection
Internal supply for digital inputs and PoE 24 V DC 21...27 V <= 200 mA overload and short-circuit protection External supply for digital inputs 24 V DC 19...30 V External supply for control circuit 100...240 V AC 47...63 Hz External supply for control circuit 120...370 V DC +/- 10 % 1 kVA Auxiliary power supply 230 V AC +/- 10 % External supply for cooling fan 400 V AC +/- 10 % 12 kVA |
|
analogue input number |
8
0 3 |
|
analogue input type |
Configurable voltage 0...10 V DC 30 kOhm 12 bits
Configurable current 0...20 mA 250 Ohm 12 bits |
|
discrete input number |
10
|
|
discrete input type |
Programmable DI1...DI8 24 V DC <= 30 V 3.5 kOhm
Programmable as pulse input DI7, DI8 0...30 kHz 24 V DC <= 30 V PWM output enable POEA, POEB 24 V DC <= 30 V > 2.2 kOhm |
|
analogue output number |
2
|
|
analogue output type |
Configurable voltage 0...10 V DC 470 Ohm 10 bits
Configurable current 0...20 mA 500 Ohm 10 bits |
|
discrete output number |
2
|
|
discrete output type |
Logic output <= 30 V DC < 100 mA
|
|
relay output number |
3
|
|
relay output type |
Configurable relay logic R1 fault relay NO/NC
Configurable relay logic R2 sequence relay NO Configurable relay logic R3 sequence relay NO |
|
isolation |
Electrical between power and control
|
|
overvoltage category |
II EN/IEC 61800-5-1 motor side
III EN/IEC 61800-5-1 line side III EN/IEC 61800-5-1 low voltage connections |
electromagnetic compatibility |
Conducted radio-frequency immunity test level 3 IEC 61000-4-6
1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5 Electrical fast transient/burst immunity test level 4 IEC 61000-4-4 Electrostatic discharge immunity test level 3 IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 |
|
---|---|---|
pollution degree |
2 EN/IEC 61800-5-1
|
|
environmental characteristic |
3K3 EN/IEC 60721-3-3
3B1 EN/IEC 60721-3-3 3C2 EN/IEC 60721-3-3 3S1 EN/IEC 60721-3-3 3M1 EN/IEC 60721-3-3 |
|
relative humidity |
5...95 % without condensation IEC 60068-2-3
|
|
ambient air temperature for operation |
-25...70 °C during transport
40...50 °C with current derating of 2 % per °C 0...40 °C |
|
ambient air temperature for storage |
0...50 °C
|
|
operating altitude |
<= 1000 m without derating
1000...2000 m with current derating 1 % per 100 m |
|
standards |
EN/IEC 61800-3
EN/IEC 61800-5-1 EN/IEC 60529 EN/IEC 61800-4 IEEE 519 1992 EN/IEC 60076 |
|
marking |
EAC
CE |
Schneider ATV6000C213A3333NA3 Medium Voltage Variable Speed Drive ATV6000 - 3.3 kV - 2130 kVA,ATV6000C213A
- Brand: Schneider
- Product Code: ATV6000C213A3333NA3
- Availability: 1000
Tags: ATV6000C213A3333NA3